Felrapper

Wrapping Machines





Electrical Tests

A Standard 100V Neon Circuit Tester can be used for this procedure.

Checking The Fuse

With the power OFF, disconnect the red wire from terminal 1 and secure it out of the way without touching any metal parts. With power ON test across terminals 3&4. If tester does not light, replace fuse.

Checking The Hot Rod

With the power OFF, disconnect the red wire from terminal 1 and secure it out of the way without touching any metal parts. With the power ON test between terminal 1 and end of wire disconnected from same terminal. If tester does not light, replace hot rod.

Check the Circuit Board