Felrapper

Wrapping Machines





Electrical Tests

A Standard 100V Neon Circuit Tester can be used for this procedure.

Checking The Fuse

With the power OFF, disconnect the red wire from terminal 1 and secure it out of the way without touching any metal parts. With power ON test across terminals 3&4. If tester does not light, replace fuse.

Checking The Hot Rod

With the power OFF, disconnect the red wire from terminal 1 and secure it out of the way without touching any metal parts. With the power ON test between terminal 1 and end of wire disconnected from same terminal. If tester does not light, replace hot rod.

Check the Circuit Board

With the power OFF, disconnect the red wire from terminal 1 and secure it out of the way without touching any metal parts. With power ON, test across terminals 1 & 2. If tester does not light, replace circuit board.


Comercial Laundry, Supermarket wrapping machines and wrapping stock. Laundry Wrap, Laundry Wrap Machine, Laundry Wrapper, Wrapping Machines, Stretch Wrapper, Laundry, Wrap, Machines, Wrapper, Felrap, Felrap World, Supermarket Wrapping Machines, Supermarket, commercial wrapping, commercial wrap, meat wrapping, meat wrap